A four-pixel matched collimator for high-sensitivity SPECT imaging

Suzuki et al., 2013

Document ID
14883572603578628239
Author
Suzuki A
Takeuchi W
Ishitsu T
Tsuchiya K
Ueno Y
Kobashi K
Publication year
Publication venue
Physics in Medicine and Biology

External Links

Snippet

We propose a wide aperture parallel-hole collimator that we call a 4-pixel matched collimator (4-PMC) for high-sensitivity SPECT imaging. The hole size of the 4-PMC is matched to four detector pixels; that is, there are four (2× 2) pixels per collimator hole. By …
Continue reading at iopscience.iop.org (other versions)

Classifications

    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/29Measurement performed on radiation beams, e.g. position or section of the beam; Measurement of spatial distribution of radiation
    • G01T1/2914Measurement of spatial distribution of radiation
    • G01T1/2985In depth localisation, e.g. using positron emitters; Tomographic imaging (longitudinal and transverse section imaging; apparatus for radiation diagnosis sequentially in different planes, steroscopic radiation diagnosis)
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/161Application in the field of nuclear medicine, e.g. in vivo counting
    • G01T1/164Scintigraphy
    • G01T1/1641Static instruments for imaging the distribution of radioactivity in one or two dimensions using one or several scintillating elements; Radio-isotope cameras
    • G01T1/1647Processing of scintigraphic data
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/161Application in the field of nuclear medicine, e.g. in vivo counting
    • G01T1/164Scintigraphy
    • G01T1/1641Static instruments for imaging the distribution of radioactivity in one or two dimensions using one or several scintillating elements; Radio-isotope cameras
    • G01T1/1648Ancillary equipment for scintillation cameras, e.g. reference markers, devices for removing motion artifacts, calibration devices
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/29Measurement performed on radiation beams, e.g. position or section of the beam; Measurement of spatial distribution of radiation
    • G01T1/2914Measurement of spatial distribution of radiation
    • G01T1/2921Static instruments for imaging the distribution of radioactivity in one or two dimensions; Radio-isotope cameras
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/24Measuring radiation intensity with semiconductor detectors
    • GPHYSICS
    • G06COMPUTING; CALCULATING; COUNTING
    • G06TIMAGE DATA PROCESSING OR GENERATION, IN GENERAL
    • G06T11/002D [Two Dimensional] image generation
    • G06T11/003Reconstruction from projections, e.g. tomography
    • G06T11/005Specific pre-processing for tomographic reconstruction, e.g. calibration, source positioning, rebinning, scatter correction, retrospective gating
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/02Dosimeters

Similar Documents

Publication Publication Date Title
Hutton et al. Review and current status of SPECT scatter correction
Surti et al. Impact of detector design on imaging performance of a long axial field-of-view, whole-body PET scanner
Surti et al. Study of PET scanner designs using clinical metrics to optimize the scanner axial FOV and crystal thickness
Abbaszadeh et al. Positioning true coincidences that undergo inter-and intra-crystal scatter for a sub-mm resolution cadmium zinc telluride-based PET system
Conti et al. Reconstruction of scattered and unscattered PET coincidences using TOF and energy information
Stockhoff et al. High-resolution monolithic LYSO detector with 6-layer depth-of-interaction for clinical PET
McNamara et al. Towards optimal imaging with PET: an in silico feasibility study
Suzuki et al. High-sensitivity brain SPECT system using cadmium telluride (CdTe) semiconductor detector and 4-pixel matched collimator
Spinks et al. Quantitative PET and SPECT performance characteristics of the Albira Trimodal pre-clinical tomograph
Lee et al. Novel inter-crystal scattering event identification method for PET detectors
Thoen et al. Influence of detector pixel size, TOF resolution and DOI on image quality in MR-compatible whole-body PET
Van Audenhaege et al. Design and simulation of a full-ring multi-lofthole collimator for brain SPECT
Surti et al. Impact of event positioning algorithm on performance of a whole-body PET scanner using one-to-one coupled detectors
Watanabe et al. Development of an omnidirectional gamma-ray imaging Compton camera for low-radiation-level environmental monitoring
Vicente et al. Improved dead-time correction for PET scanners: application to small-animal PET
Jan et al. PSF reconstruction for Compton-based prompt gamma imaging
Suzuki et al. A four-pixel matched collimator for high-sensitivity SPECT imaging
Bouckaert et al. Evaluation of a compact, high-resolution SPECT detector based on digital silicon photomultipliers
Mikhaylova et al. Optimization of an ultralow-dose high-resolution pediatric PET scanner design based on monolithic scintillators with dual-sided digital SiPM readout: a simulation study
Efthimiou et al. Data-driven, energy-based method for estimation of scattered events in positron emission tomography
Shy et al. Gamma-ray tracking for high energy gamma-ray imaging in pixelated CdZnTe
Sakai et al. Effect of number of views on cross-sectional Compton imaging: A fundamental study with backprojection
Gillam et al. Simulated one-pass list-mode: an approach to on-the-fly system matrix calculation
Brzeziński et al. Study of a high-resolution PET system using a silicon detector probe
Bowen et al. Design and performance evaluation of a 20-aperture multipinhole collimator for myocardial perfusion imaging applications