In this paper, the performance of the EGLA (Externally Gaped Line Arresters) and its impact on the back flashover rate of a 400 kV Transmission Line have been investigated. The frequency behavior of the grounding system and soil resistivity has been modeled. To …
Continue reading at www.sid.ir (PDF) (other versions)

Classifications

    • HELECTRICITY
    • H02GENERATION; CONVERSION OR DISTRIBUTION OF ELECTRIC POWER
    • H02HEMERGENCY PROTECTIVE CIRCUIT ARRANGEMENTS
    • H02H9/00Emergency protective circuit arrangements for limiting excess current or voltage without disconnection
    • H02H9/04Emergency protective circuit arrangements for limiting excess current or voltage without disconnection responsive to excess voltage
    • H02H9/06Emergency protective circuit arrangements for limiting excess current or voltage without disconnection responsive to excess voltage using spark-gap arresters
    • HELECTRICITY
    • H02GENERATION; CONVERSION OR DISTRIBUTION OF ELECTRIC POWER
    • H02HEMERGENCY PROTECTIVE CIRCUIT ARRANGEMENTS
    • H02H9/00Emergency protective circuit arrangements for limiting excess current or voltage without disconnection
    • H02H9/04Emergency protective circuit arrangements for limiting excess current or voltage without disconnection responsive to excess voltage
    • H02H9/042Emergency protective circuit arrangements for limiting excess current or voltage without disconnection responsive to excess voltage comprising means to limit the absorbed power or indicate damaged over-voltage protection device
    • HELECTRICITY
    • H01BASIC ELECTRIC ELEMENTS
    • H01TSPARK GAPS; OVERVOLTAGE ARRESTERS USING SPARK GAPS; SPARKING PLUGS; CORONA DEVICES; GENERATING IONS TO BE INTRODUCED INTO NON-ENCLOSED GASES
    • H01T4/00Overvoltage arresters using spark gaps
    • H01T4/08Overvoltage arresters using spark gaps structurally associated with protected apparatus

Similar Documents

Publication Publication Date Title
Guo et al. Reignition overvoltages induced by vacuum circuit breakers and its suppression in offshore wind farms
Araujo et al. Practical methodology for modeling and simulation of a lightning protection system using metal-oxide surge arresters for distribution lines
Ahmadi et al. Enhancing the lightning performance of overhead transmission lines with optimal EGLA and downstream shield wire placement in mountainous areas: A complete study
Datsios et al. Investigation of line surge arresters application to the 150 kV system of Rhodes
Vita et al. Comparison of metal-oxide surge arresters circuit models and implementation on high-voltage transmission lines of the Hellenic network
CN114089009A (en) Inrush current suppression type voltage transformer based on current sensitive resistor technology
Jiang et al. Experimental and analytical investigation of the effects of single and multiple simulated lightning impulse currents on metal-oxide arrester blocks
Kisielewicz et al. Stress to surge protective devices system due to direct flashes to low voltage lines
Khodsuz Frequency Grounding System Effect on the EGLAs Placement in a 400 kV Transmission Line
Amiri Analysis and comparison of actual behavior of oil-type and dry-type transformers during lightning
Mitra et al. Resonant behavior of EHV transformer windings under system originated oscillatory transient over voltages
Martinez-Velasco et al. Surge arresters
Gholami et al. The Lightning Protection Assessment of Distribution Lines with Considering Frequency Grounding System.
Emrose et al. Lightning performance analysis on 400 kV transmission line of Bangladesh power system network
Mohammadhosein et al. The consequence of ignoring load modeling on the circuit breaker selection in densely-meshed sub-transmission systems
Ruiz et al. Study of Application of Transmission Line Arrester (TLA), Modeling and Results in 220 kV Systems
Motilal et al. Power transformer and surge arrester modeling for fast front overvoltages using EMTP-RV
Nugroho et al. Impact of arrester models in placement determination at 150 kV Srondol substation
Radhika et al. Effective Placement of Surge Arrestor during Lightning
Jurisic et al. CALCULATION OF FAST FRONT OVERVOLTAGES IN VICINITY OF A POWER TRANSFORMER
Hosseini et al. Reliability Analysis of Surge Arrester Location Effect in High voltage substations
Jurišić et al. Calculation of Lightning and Switching Overvoltages Transferred through Power Transformer
Sultan Study and Investigation of The Effects of Shielding Failure and Lightning Arrester Position in A 220kV Substation on Lightning Strokes
He et al. Influence of different factors on coordination of two cascaded SPDs
Hadjicostas et al. Modeling Sheath Voltage Limiters for Lightning-Related Transient Studies